Apendix 1 all results.xlsx/"data for Ap 1"
Entity (ENT) | Alaska Fisheries Science Center (AFSC)GUID: gov.noaa.nmfs.inport:23085 | Updated: August 9, 2022 | Published / External
Item Identification
Title: | Apendix 1 all results.xlsx/"data for Ap 1" |
---|---|
Short Name: | Apendix 1 all results.xlsx/"data for Ap 1" |
Status: | In Work |
Abstract: |
READERS. Links or combines age determination results from multiple methods, multiple readers, and several versions (from production age reading procedures) to the biological data for each specimen in the study. |
Notes: |
Loaded by FGDC Metadata Uploader, batch 5317, 02-04-2015 12:15 |
Entity Information
Description: |
READERS. Links or combines age determination results from multiple methods, multiple readers, and several versions (from production age reading procedures) to the biological data for each specimen in the study. |
---|
Data Attributes
Attribute Summary
Name | Type | Description | ||
---|---|---|---|---|
100
|
SPECIMEN_ID | NUMBER | Specimen ID number. NOTE: Specimen numbers are within cruise, so there can be repeats in this sheet. | |
100
|
CRUISE_ID | NUMBER | Concatenated cruise number and species code 202_specimen number. NOTE: Specimen numbers are within cruise, so there can be multiple repeats in sheet. | |
100
|
AGE | NUMBER | age assigned to the specimen, in years, by the Age and Growth Program | |
100
|
CUP_NUM | NUMBER | Sample number within a specimen (also cup number in sample holder). | |
100
|
PATH_NAME | Unknown | assigned to path for latter association of milling location in image of thin section. | |
100
|
WIDTH_MM | NUMBER | Width of each path cut by mill. | |
100
|
RUNNING_SUM_OF_WIDTH_MM | NUMBER | Distance milled as milling progressed through otolith thin section. | |
100
|
LENGTH_MM | NUMBER | Length of each path cut by mill. | |
100
|
DEPTH_UM | NUMBER | Depth of milling for each path cut by mill. | |
100
|
WEIGHT_UG | NUMBER | Weight of each sample, generated by milling. | |
100
|
MASS_44_MV | NUMBER | Mass 44 (mV) is the yield in millivolts of CO2 gas with an atomic mass of 44. It is used to monitor the amount of gas going into the source of the mass spectrometer. | |
100
|
PRESSURE_ADJUST_MV | NUMBER | Pressure Adjust (mV) is the difference between the amount of reference and sample gas (measured in millivolts) going into the mass spectrometer source during the analysis of a sample. In dual inlet IRMS this value must be minimized (i.e., pressures on the sample and reference side must be similar) to produce good results. | |
100
|
d13C_PERMIL_VPDB | NUMBER | Result of mass spectrometer measurement for d13C, permill VPDB (Vienna Pee Dee Belemnite). | |
100
|
SD_dC13 | NUMBER | One standard deviation of d13C measurement. | |
100
|
d18O_PERMIL_VPDB | NUMBER | Result of mass spectrometer measurement for d18O, permill VPDB (Vienna Pee Dee Belemnite). | |
100
|
SD_d18O | NUMBER | One standard deviation of d18O measurement. | |
100
|
MS_COMMENTS | Unknown | Any annotated comments relative to mass spec. |
Attribute Details
SPECIMEN_ID
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Specimen ID number. NOTE: Specimen numbers are within cruise, so there can be repeats in this sheet. |
Allowed Values: | 6 - 864 |
CRUISE_ID
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Concatenated cruise number and species code 202_specimen number. NOTE: Specimen numbers are within cruise, so there can be multiple repeats in sheet. |
Allowed Values: | 88200601202 - 162201001202 |
AGE
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
age assigned to the specimen, in years, by the Age and Growth Program |
Unit of Measure: | year |
Allowed Values: | 2 - 5 |
CUP_NUM
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Sample number within a specimen (also cup number in sample holder). |
Allowed Values: | 1 - 42 |
PATH_NAME
Data Storage Type: | Unknown |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
assigned to path for latter association of milling location in image of thin section. |
Allowed Values: | text |
WIDTH_MM
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Width of each path cut by mill. |
Unit of Measure: | millimeter |
Allowed Values: | 0.02 - 3.3 |
RUNNING_SUM_OF_WIDTH_MM
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Distance milled as milling progressed through otolith thin section. |
Unit of Measure: | millimeter |
Allowed Values: | 0 - 2 |
LENGTH_MM
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Length of each path cut by mill. |
Unit of Measure: | millimeter |
Allowed Values: | 0.02 - 94 |
DEPTH_UM
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Depth of milling for each path cut by mill. |
Unit of Measure: | micrometers |
Allowed Values: | 7.5 - 300 |
WEIGHT_UG
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Weight of each sample, generated by milling. |
Unit of Measure: | micrograms |
Allowed Values: | 0 - 228 |
MASS_44_MV
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Mass 44 (mV) is the yield in millivolts of CO2 gas with an atomic mass of 44. It is used to monitor the amount of gas going into the source of the mass spectrometer. |
Unit of Measure: | millivolts |
Allowed Values: | 1 - 3592.666667 |
PRESSURE_ADJUST_MV
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Pressure Adjust (mV) is the difference between the amount of reference and sample gas (measured in millivolts) going into the mass spectrometer source during the analysis of a sample. In dual inlet IRMS this value must be minimized (i.e., pressures on the sample and reference side must be similar) to produce good results. |
Unit of Measure: | millivolts |
Allowed Values: | -751 - 17.5 |
d13C_PERMIL_VPDB
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Result of mass spectrometer measurement for d13C, permill VPDB (Vienna Pee Dee Belemnite). |
Unit of Measure: | permil/VPDB |
Allowed Values: | -4.584471703 - 0.814258575 |
SD_dC13
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
One standard deviation of d13C measurement. |
Allowed Values: | 0.01 - 0.03 |
d18O_PERMIL_VPDB
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Result of mass spectrometer measurement for d18O, permill VPDB (Vienna Pee Dee Belemnite). |
Unit of Measure: | permil/VPDB |
Allowed Values: | -2.98 - 2.81 |
SD_d18O
Data Storage Type: | NUMBER |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
One standard deviation of d18O measurement. |
Allowed Values: | 0.01 - 0.08 |
MS_COMMENTS
Data Storage Type: | Unknown |
---|---|
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Any annotated comments relative to mass spec. |
Allowed Values: | text |
Catalog Details
Catalog Item ID: | 23085 |
---|---|
GUID: | gov.noaa.nmfs.inport:23085 |
Metadata Record Created By: | Angie Greig |
Metadata Record Created: | 2015-02-04 12:15+0000 |
Metadata Record Last Modified By: | SysAdmin InPortAdmin |
Metadata Record Last Modified: | 2022-08-09 17:11+0000 |
Metadata Record Published: | 2016-04-28 |
Owner Org: | AFSC |
Metadata Publication Status: | Published Externally |
Do Not Publish?: | N |
Metadata Last Review Date: | 2016-04-28 |
Metadata Review Frequency: | 1 Year |
Metadata Next Review Date: | 2017-04-28 |