Slide Menu
Search Help Show/Hide Menu

Item Identification

Title: Apendix 1 all results.xlsx/"data for Ap 1"
Short Name: Apendix 1 all results.xlsx/"data for Ap 1"
Status: In Work
Abstract:

READERS. Links or combines age determination results from multiple methods, multiple readers, and several versions (from production age reading procedures)

to the biological data for each specimen in the study.

Notes:

Loaded by FGDC Metadata Uploader, batch 5317, 02-04-2015 12:15

Entity Information

Description:

READERS. Links or combines age determination results from multiple methods, multiple readers, and several versions (from production age reading procedures)

to the biological data for each specimen in the study.

Data Attributes

Attribute Summary

Rubric Score Primary Key? Name Type Description
100
SPECIMEN_ID NUMBER Specimen ID number. NOTE: Specimen numbers are within cruise, so there can be repeats in this sheet.
100
CRUISE_ID NUMBER Concatenated cruise number and species code 202_specimen number. NOTE: Specimen numbers are within cruise, so there can be multiple repeats in sheet.
100
AGE NUMBER age assigned to the specimen, in years, by the Age and Growth Program
100
CUP_NUM NUMBER Sample number within a specimen (also cup number in sample holder).
100
PATH_NAME Unknown assigned to path for latter association of milling location in image of thin section.
100
WIDTH_MM NUMBER Width of each path cut by mill.
100
RUNNING_SUM_OF_WIDTH_MM NUMBER Distance milled as milling progressed through otolith thin section.
100
LENGTH_MM NUMBER Length of each path cut by mill.
100
DEPTH_UM NUMBER Depth of milling for each path cut by mill.
100
WEIGHT_UG NUMBER Weight of each sample, generated by milling.
100
MASS_44_MV NUMBER Mass 44 (mV) is the yield in millivolts of CO2 gas with an atomic mass of 44. It is used to monitor the amount of gas going into the source of the mass spectrometer.
100
PRESSURE_ADJUST_MV NUMBER Pressure Adjust (mV) is the difference between the amount of reference and sample gas (measured in millivolts) going into the mass spectrometer source during the analysis of a sample. In dual inlet IRMS this value must be minimized (i.e., pressures on the sample and reference side must be similar) to produce good results.
100
d13C_PERMIL_VPDB NUMBER Result of mass spectrometer measurement for d13C, permill VPDB (Vienna Pee Dee Belemnite).
100
SD_dC13 NUMBER One standard deviation of d13C measurement.
100
d18O_PERMIL_VPDB NUMBER Result of mass spectrometer measurement for d18O, permill VPDB (Vienna Pee Dee Belemnite).
100
SD_d18O NUMBER One standard deviation of d18O measurement.
100
MS_COMMENTS Unknown Any annotated comments relative to mass spec.

Attribute Details

SPECIMEN_ID

CC ID: 188098
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Specimen ID number. NOTE: Specimen numbers are within cruise, so there can be repeats in this sheet.

Allowed Values: 6 - 864

CRUISE_ID

CC ID: 188099
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Concatenated cruise number and species code 202_specimen number. NOTE: Specimen numbers are within cruise, so there can be multiple repeats in sheet.

Allowed Values: 88200601202 - 162201001202

AGE

CC ID: 188100
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

age assigned to the specimen, in years, by the Age and Growth Program

Unit of Measure: year
Allowed Values: 2 - 5

CUP_NUM

CC ID: 188101
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Sample number within a specimen (also cup number in sample holder).

Allowed Values: 1 - 42

PATH_NAME

CC ID: 188102
Data Storage Type: Unknown
Required: No
Primary Key: No
Status: Active
Description:

assigned to path for latter association of milling location in image of thin section.

Allowed Values: text

WIDTH_MM

CC ID: 188103
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Width of each path cut by mill.

Unit of Measure: millimeter
Allowed Values: 0.02 - 3.3

RUNNING_SUM_OF_WIDTH_MM

CC ID: 188104
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Distance milled as milling progressed through otolith thin section.

Unit of Measure: millimeter
Allowed Values: 0 - 2

LENGTH_MM

CC ID: 188105
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Length of each path cut by mill.

Unit of Measure: millimeter
Allowed Values: 0.02 - 94

DEPTH_UM

CC ID: 188106
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Depth of milling for each path cut by mill.

Unit of Measure: micrometers
Allowed Values: 7.5 - 300

WEIGHT_UG

CC ID: 188107
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Weight of each sample, generated by milling.

Unit of Measure: micrograms
Allowed Values: 0 - 228

MASS_44_MV

CC ID: 188108
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Mass 44 (mV) is the yield in millivolts of CO2 gas with an atomic mass of 44. It is used to monitor the amount of gas going

into the source of the mass spectrometer.

Unit of Measure: millivolts
Allowed Values: 1 - 3592.666667

PRESSURE_ADJUST_MV

CC ID: 188109
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Pressure Adjust (mV) is the difference between the amount of reference and sample gas (measured in millivolts) going into

the mass spectrometer source during the analysis of a sample. In dual inlet IRMS this value must be minimized (i.e., pressures on

the sample and reference side must be similar) to produce good results.

Unit of Measure: millivolts
Allowed Values: -751 - 17.5

d13C_PERMIL_VPDB

CC ID: 188110
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Result of mass spectrometer measurement for d13C, permill VPDB (Vienna Pee Dee Belemnite).

Unit of Measure: permil/VPDB
Allowed Values: -4.584471703 - 0.814258575

SD_dC13

CC ID: 188111
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

One standard deviation of d13C measurement.

Allowed Values: 0.01 - 0.03

d18O_PERMIL_VPDB

CC ID: 188112
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

Result of mass spectrometer measurement for d18O, permill VPDB (Vienna Pee Dee Belemnite).

Unit of Measure: permil/VPDB
Allowed Values: -2.98 - 2.81

SD_d18O

CC ID: 188113
Data Storage Type: NUMBER
Required: No
Primary Key: No
Status: Active
Description:

One standard deviation of d18O measurement.

Allowed Values: 0.01 - 0.08

MS_COMMENTS

CC ID: 188114
Data Storage Type: Unknown
Required: No
Primary Key: No
Status: Active
Description:

Any annotated comments relative to mass spec.

Allowed Values: text

Catalog Details

Catalog Item ID: 23085
GUID: gov.noaa.nmfs.inport:23085
Metadata Record Created By: Angie Greig
Metadata Record Created: 2015-02-04 12:15+0000
Metadata Record Last Modified By: SysAdmin InPortAdmin
Metadata Record Last Modified: 2022-08-09 17:11+0000
Metadata Record Published: 2016-04-28
Owner Org: AFSC
Metadata Publication Status: Published Externally
Do Not Publish?: N
Metadata Last Review Date: 2016-04-28
Metadata Review Frequency: 1 Year
Metadata Next Review Date: 2017-04-28